 WWW.PHIHONG.COM
30W Power Over Ethernet Adapter High Power, high temperature single port injector.
Features
* * * * * * * * * * * * * Fully Compliant detection, disconnect and voltage control IEEE802.3af Diagnostic LEDs Non-Vented Case Wide temperature range -20 to +55C IP Telephones Wireless Network Access Points Blue Tooth Access Point
* * * * *
UNH IOL Tested Full Protection OCP, OVP Gigabit Compatible
Applications
Security Camera IP Print Servers
Safety Approvals
cUL/UL CE Korea K Argentina IRAM Length: 166mm (6.48in) Width: 80mm (3.15in)
* * * * *
China CCC Australia SAA & C-Tick Japan
Mechanical Characteristics
Height: 43.6mm (1.72in) Weight: 0.3Kg (0.5lb.)
Output Specifications Model
POE30U-560GHT
DC Output Voltage
56V 0A
Load Min. Max.
0.55A
Regulation Line Load
54-57Vdc under all conditions
Ripple And Noise* <500Hz 500Hz-150KHz 150KHz-500KHz 500KHz-1MHz
Vp-p* 0.5 0.15 0.15 0.1
*As per IEEE802.3af Table 33-5.
Phihong is not responsible for any error and change. Content is subject to change without notice. Please consult the factory and visit www.phihong.com for the most up-to-date specifications.
POE30U-560GHT Characteristics INPUT:
AC Input Voltage Range
90 to 264VAC
WWW.PHIHONG.COM
EMC
FCC Part 15 Class B EN55022 Class B
AC Input Voltage Rating
100 to 240VAC,47-63Hz
Isolation Test
Primary to Secondary: 3000VAC for 1 minute 10mA Primary to F.G.: 1500VAC for 1 minute Output to F.G.: 1500VAC
AC Input Current
0.5A(RMS) max. for 90VAC 0.35A(RMS) max. for 240VAC
Immunity Leakage Current
1.0 mA max. @ 254VAC 60Hz ESD: RS: EFT: Surge: CS: Voltage Dips Harmonic: EN61000-4-2. Level 3 EN61000-4-3. Level 2 EN61000-4-4. Level 2 EN61000-4-5. Level 3 EN61000-4-6. Level 2 EN61000-4-11 EN61000-3-2
AC Inrush Current
15A(RMS) max. for 115VAC 20A(RMS) max. for 230VAC
OUTPUT:
Total Output Power
30W
Insulation Resistance
Primary to secondary: >10M OHM 500VDC Primary to FC: >10M OHM 500VDC
DC Offset
No Data degradation with DC imbalance 18mA
FEATURE:
Over Voltage/Current, Short Circuit Protection
Outputs equipped with short circuit protection and overload protection as per 802.3af specification except max average current is 0.55A, Peak 0.6A The output can be shorted permanently without damage
Efficiency
65% (typical) at Max. load, and 120VAC 60Hz
Hold-up Time
16mS min. 120VAC and max. load
Indicators
Led #1 indicator for input power "on" GREEN Led #2 Indicator for fault-RED Led #3 Indicator that Detected and Connected to valid IEEE802.3af load-GREEN
Transient O/P Voltage Protection
60V max.
ENVIRONMENTAL:
Temperature
Operation Non-operation -20 to +55C -40 to +71C
Input Connector
IEC320 inlet 3 pin
Humidity
Operation 5 to 90%
Output Connection +pins 3,6 - pins 1,2
Dimension Diagram Unit: mm (inch)
Gigabit Power Injector Block Diagram
Power-up Sequence:
Description of LED Functions for Gigabit Power Injector
Upon power-up, all 3 LEDs will light for 2 seconds, as part of the self-test for the internal microprocessor software. After the end of the 2 seconds, the "ON" LED will illuminate green, signifying that the DC output voltage is available for powering a compliant load (to the 802.3af PoE standards). Detection Sequence: Once a compliant load is attached to the output RJ45 connector, the green "CONNECT" LED will illuminate. Should the load be non-compliant then the LEDs will blink a code signifying the cause for non-detection. Detection Failure Codes: 1. 2. 3. 4. 5. Incorrect resistive signature - The green "CONNECT" and red "FAULT" LEDs will blink 3 times. Incorrect capacitive signature - The green "ON" LED will blink 3 times. Incorrect Voffset - The green "CONNECT" and green "ON" LEDs will blink 3 times. Unstable current measurement - The green "CONNECT" LED will blink 3 times Low voltage sensed during detection (overload) - The red "FAULT" LED will blink 3 times
Formatted: Indent: Left: -0.5", Hanging: 1"
After the LEDs blink 3 times the PSEwill continue to try to detect a valid load. Therefore, until the correct load is applied, the LEDs will continue to blink. If there is an open circuit connected to the output RJ45 then the LEDs will not blink but the PSE will continue to try to detect a valid load. Fault Sequence: Should there be a fault such as an overload or short circuit then the red "FAULT" LED will illuminate. The red "FAULT" LED will illuminate for 2 seconds and then go off as the power supply tries to redetect a valid load. If there is a problem in detecting, the LED will indicate what is wrong with the load as per the codes in the section above..
Formatted: Indent: Left: 0.5", Right: 0.01", Tab stops: 0.5", Left


▲Up To Search▲   

 
Price & Availability of POE30U-560GHT

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X